Buy Online
Product model
TA8315A / TA8315B / TA8315C / TA8315D / TA8315E
Product features

True RMS measurement

The jaw can be opened to 27mm

NCV non contact voltage measurement

Backlight display    on-off alarm    diode measurement     value lock     low voltage prompt

Flashlight lighting function (TA8315B / C / D / E only)

On off beep test alarm function

Compact design

High precision measurement

Product parameters
 Product model TA8315A TA8315B TA8315C TA8315D TA8315E
 DC voltage 0.1mV~1000V 1mV~1000V 1mV~1000V 1mV~1000V 0.6V~600V
 ±(0.5%+3) ±(0.5%+3) ±(0.5%+3) ±(0.5%+3) ±(0.5%+3)
 AC voltage 1mV~750V 1mV~750V 1mV~750V 1mV~750V 0.6V~600V
 ±(1.2%+10) ±(1.2%+10) ±(1.2%+10) ±(1.2%+10) ±(0.8%+10)
 DC current - - - 0.1A~600A -
 AC current 0.01A~600A 0.01A~600A 0.01A~600A 0.6A~600A 15mA~600A
 ±(3.0%+10) ±(3.0%+10) ±(3.0%+10) ±(3.0%+10) ±(2%+30)
 Resistance measurement 1Ω~40MΩ 1Ω~40MΩ 1Ω~40MΩ 0.1Ω~40MΩ 0.1Ω~60MΩ
 ±(1.2%+8) ±(1.2%+8) ±(1.2%+8) ±(1.2%+8) ±(2.5%+3)
 Capacitance measurement - - 1nF~30000μF 1nF~30000μF 10nF~60000μF
 ±(5.0%+10) ±(5.0%+10) ±(5%+3)
 Frequency measurement - 10Hz~10MHz 10Hz~10MHz 10Hz~10MHz -
 ±(0.1%+3) ±(0.1%+3) ±(0.1%+3)
 Temperature measurement - -20~1000°C -20~1000°C -20~1000°C -
 ±(1°C) ±(1°C) ±(1°C)
 Square wave output - - 50Hz~5000Hz 50Hz~5000Hz -
 On off beep  
 Diode measurement  
 Max / min value   Max value measurement Max value measurement - -
 Flashlight lighting -    
 Maximum display 3999(3 3/4) Digit 5999(3 5/6) Digit 5999(3 5/6) Digit 5999(3 5/6) Digit 5999(3 5/6) Digit
 Automatic shutdown About 15 minutes
 Measurement method Double integral A / D conversion
 Sampling frequency 3 times per second 
 Jaw open 27mm
 Product power supply AAAX2 batteries
 Others NCV measurement      true RMS    backlight display     on-off alarm     diode measurement    value lock
 low voltage prompt
 Working environment temperature 0  to 50 
 Working environment humidity 10 ~ 95% RH - non condensing
 Storage temperature -20  to 60  (excluding battery)
 Standard accessories Cloth bag, instruction manual, one pair of probes, K-type thermocouple temperature probe (only available for TA8315B / C / D)
 Package size 176x67x33mm
 Package method Color box+Cloth bag
 Product net weight About 300g (including battery)
 Individual package size 207x115x43mm
 Individual package weight 0.383kg
 Standard outer box volume (L x W x H) 45x42x25cm
 Standard packing quantity 40PCS
 Standard packing weight 16.3kg

*Product specifications are subject to change without prior notice, please understand.

Suzhou TASI Electronics Co.,Ltd.

Add: 5th Floor, Building 5, No. 317, Mudong Road, Wuzhong District, Suzhou City, Jiangsu Province, China.

Tel: 0086-0512- 68057436

Email: sales@china-tasi.com