True RMS measurement
The jaw can be opened to 27mm
NCV non contact voltage measurement
Backlight display on-off alarm diode measurement value lock low voltage prompt
Flashlight lighting function (TA8315B / C / D / E only)
On off beep test alarm function
Compact design
High precision measurement
Product model | TA8315A | TA8315B | TA8315C | TA8315D | TA8315E |
DC voltage | 0.1mV~1000V | 1mV~1000V | 1mV~1000V | 1mV~1000V | 0.6V~600V |
±(0.5%+3) | ±(0.5%+3) | ±(0.5%+3) | ±(0.5%+3) | ±(0.5%+3) | |
AC voltage | 1mV~750V | 1mV~750V | 1mV~750V | 1mV~750V | 0.6V~600V |
±(1.2%+10) | ±(1.2%+10) | ±(1.2%+10) | ±(1.2%+10) | ±(0.8%+10) | |
DC current | - | - | - | 0.1A~600A | - |
AC current | 0.01A~600A | 0.01A~600A | 0.01A~600A | 0.6A~600A | 15mA~600A |
±(3.0%+10) | ±(3.0%+10) | ±(3.0%+10) | ±(3.0%+10) | ±(2%+30) | |
Resistance measurement | 1Ω~40MΩ | 1Ω~40MΩ | 1Ω~40MΩ | 0.1Ω~40MΩ | 0.1Ω~60MΩ |
±(1.2%+8) | ±(1.2%+8) | ±(1.2%+8) | ±(1.2%+8) | ±(2.5%+3) | |
Capacitance measurement | - | - | 1nF~30000μF | 1nF~30000μF | 10nF~60000μF |
±(5.0%+10) | ±(5.0%+10) | ±(5%+3) | |||
Frequency measurement | - | 10Hz~10MHz | 10Hz~10MHz | 10Hz~10MHz | - |
±(0.1%+3) | ±(0.1%+3) | ±(0.1%+3) | |||
Temperature measurement | - | -20~1000°C | -20~1000°C | -20~1000°C | - |
±(1°C) | ±(1°C) | ±(1°C) | |||
Square wave output | - | - | 50Hz~5000Hz | 50Hz~5000Hz | - |
On off beep | √ | ||||
Diode measurement | √ | ||||
Max / min value | √ | Max value measurement | Max value measurement | - | - |
Flashlight lighting | - | √ | √ | √ | √ |
Maximum display | 3999(3 3/4) Digit | 5999(3 5/6) Digit | 5999(3 5/6) Digit | 5999(3 5/6) Digit | 5999(3 5/6) Digit |
Automatic shutdown | About 15 minutes | ||||
Measurement method | Double integral A / D conversion | ||||
Sampling frequency | 3 times per second | ||||
Jaw open | 27mm | ||||
Product power supply | AAAX2 batteries | ||||
Others | NCV measurement true RMS backlight display on-off alarm diode measurement value lock low voltage prompt | ||||
Working environment temperature | 0 ℃ to 50 ℃ | ||||
Working environment humidity | 10 ~ 95% RH - non condensing | ||||
Storage temperature | -20 ℃ to 60 ℃ (excluding battery) | ||||
Standard accessories | Cloth bag, instruction manual, one pair of probes, K-type thermocouple temperature probe (only available for TA8315B / C / D) | ||||
Package size | 176x67x33mm | ||||
Package method | Color box+Cloth bag | ||||
Product net weight | About 300g (including battery) | ||||
Individual package size | 207x115x43mm | ||||
Individual package weight | 0.383kg | ||||
Standard outer box volume (L x W x H) | 45x42x25cm | ||||
Standard packing quantity | 40PCS | ||||
Standard packing weight | 16.3kg |
*Product specifications are subject to change without prior notice, please understand.
Add: 5th Floor, Building 5, No. 317, Mudong Road, Wuzhong District, Suzhou City, Jiangsu Province, China.
Tel: 0086-0512- 68057436
Email: sales@china-tasi.com